AFM ER70S-2 Low Alloy Wires
AWS/SFA A5.18

 

Description: AFM ER70S-2 is used primarily for single-pass welding of killed, semi-killed, and rimmed steels, but may also be used for some multipass applications. Because of the added deoxidants, AFM ER70S-2 can be used for welding steels that have a rusty or dirty surface, with a possible sacrifice of weld quality depending on the condition of the surface. Typical specifications for these steels are ASTM A36, A285-C, A515-55 and A516-70, which have UNS numbers K02600, K02801, K02001, and K02700, respectively.

Chemical Composition Requirements for Solid Electrodes and Rods:

(AL)

Aluminum

0.05-0.15 Cr

(C)

Carbon

0.07

(Cu)

Copper

0.50

(Mn)

Manganese

0.90 to 1.40

(Mo)

Molybtenum

(a)

(Ni)

Nickel

(a)

(P)

Phosphorus

0.025

(S)

Sulfer

0.035

(Si)

Silicon

0.40 to 0.70

(Ti)

Titanium

0.05 to 0.15

(V)

Vanadium

(a)

(Zr)

Tungsten

0.02 to 0.12

 

 

 

(a) These residual elements shall not exceed 0.50 in total.
All values are considered maximum, unless other-wise noted

Typical Mechanical Properties:

  • Tensile Strength, psi 80,000
  • MPa 552
  • Yield Strength, psi 65,000
  • MPa 450 Elongation, (%, 2¡±) 25
  • Charpy V-Notch (ft.-lbs. @ -20¡ÆF) 28

Standard Sizes: .030 (0.8mm), .035 (0.9mm), .045 (1.2mm), 1/16 (1.6mm), 3/32 (2.4mm), 1/8 (3.2mm), & 5/32 (4.0mm)


Click Here to Download Detailed Specification

Click Here to Download MSDS
Contact Sales